Sign In | Join Free | My burrillandco.com
Home > Solar Pump Station >

SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station

JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station from wholesalers
     
    Buy cheap SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station from wholesalers
    • Buy cheap SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station from wholesalers
    • Buy cheap SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station from wholesalers
    • Buy cheap SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station from wholesalers

    SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station

    Ask Lasest Price
    Brand Name : PASSION/OEM
    Model Number : SR11L-258,SR21L-258
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 10000units/month
    Delivery Time : 3 working days
    • Product Details
    • Company Profile

    SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station

    SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station


    SR11L/SR21L Series Solar Hot Water Pump Station with Integrated controller SR258 Max. permitted pressure 6 bar 1-20L/Min flow

    1. Solar pump station with integrated controller

    Integrated controller ,Outstanding design ,Safety assembly with safety valve,High-Quality casing for reduction of heat loses ,Flow rate checked

    1.1 Scope of delivery

    1* solar pump station

    1* integrated solar controller SR258

    1* wall mounting bracket

    1* accessory bag

    1* manual

    1.2 About this manual

    This solar pump station is a preinstalled and leak-tested group of fitting for transferring heat from the collector to the store. It contains important fittings and safety devices for the operation of the solar thermal system:

    Ball valves in flow and return in combination with check valves to prevent gravity circulation.

    Air stopper for manual bleeding of the solar thermal system

    Electronic flow rate check for displaying the flow rate

    Manometer for displaying the system pressure

    Safety valve to prevent inadmissible over pressure

    Flushing and filling unit for flushing, filling and emptying the solar thermal system.

    1.3 Safety instructions

    The installation and commissioning of the solar station as well as the connection of electrical components requires technical knowledge commensurate with a recognized vocational qualification as a fitter for plumbing, heating and air conditioning technology, or a profession requiring a comparable level of knowledge. The following must be observed during installation and commissioning:

    The relevant regional and national regulations.

    The technical and safety instructions of these instructions.

    Warning: risk of scalding

    There is danger of steam emission with safety valves. Therefore a discharge pipe must be connected to the safety assembly, please observe the enclosed instructions regarding the safety valve when doing this.

    Attention: damage of solar pump station

    The group of fittings must be installed with sufficient spacing to the collectors because temperatures in the vicinity of the collectors can be very high. An intermediate vessel may be necessary for installation in the attic.

    It is imperative that you make sure the EPDM sealing elements of the solar pump station do not come into contact with substances containing mineral oil. Mineral oil products cause lasting damage to the material, whereby its sealant properties are lost. If necessary, ask the manufacturer whether the solar fluid, fats or installation aids contain mineral oils. We don’t assume liability nor provide warranty for damage to solar station resulting from sealants damaged in this way.

    1.4 Station dimensions:

    Height ( with insulation):450mm

    Width (with insulation):300mm

    Depth (with insulation):158mm

    Distance centre:1600mm

    Distance axis/wall:55mm

    Pipe connections: 3/4’ IT

    Connection for expansion vessel set: 3/4’ET, flat sealing

    Outlet safety valve: 1/2 IT

    1.5 Specification of components

    1)Non-return valve: opening pressure 200mmH2O

    2)Connector of flow outlet (to collector):3/4’ IT

    3)Safety valve: 6bar

    4)Filling connector

    5)Connector of expansion vessel

    6) Manometer: 0-6bar

    7) Sensor on return pipe (from tank to collector),NTC10K ( optional)

    8) Circuit pump: Wilo 15-6 or Groundfos 15-65

    9) Connector of drainage valve

    10) Digital flow counter Return outlet connection (from collector): 3/4 IT

    11) Connector of flow inlet (from tank):3/4’ IT

    12) Connector of flow outlet (to tank):3/4’ IT ( no this connector on SR11L station)

    13) Air separator

    14) Manual air bleeder

    15) Sensor on flow pipe (from collector to tank),NTC10K ( optional) ( no sensor on SR11L station) 16) Connector of flow inlet (from collector):3/4’ IT


    Material:

    Fitting: Brass

    Seals: PTFE

    Insulation: EPP, λ= 0.041W/ (m.K)

    1.6 Technical Data

    Max. permitted pressure: 6bar

    Max. permitted operating temperature: 120oC

    Digital flow rate FRT: 1-20L/Min

    Solar System( Single pipeline and Double pipeline).


    Flat Panel Split Solar Water Heater

    with Double Coils PTS-F2


    Flat Panel Split Solar Water Heater
    with Double Coils PTS-F2
    ModelPTS-F2-15PTS-F2-20PTS-F2-25PTS-F2-30PTS-F2-40PTS-F2-50PTS-F2-100
    Flat Panel Solar CollectorCore materialCopper
    CoatingCopper aluminum cover coating of Blue Titanium Absorption rate: α=0.95 Reflection rate ε=0.04.
    Base plateMarine-grade H3004 Aluminum, toughnessH32 Thickness 0.7mm
    Glass of panelSpecial glass for panel With ANS1297-1-1975, BS6206A and JIS R3206 standards; toughness with AS2208-1978 and federal standards of United States.
    Panel InsulationBottom with fiberglass insulation ,Thickness 60mm,Density 20kg/m³; Side-thickness insulation:13mm; Density 23kg/m³; Thermal properties: R1.0 Thermal conductivity : 0.059W/m.
    Quantity (PCS)1122336
    Water
    Tank
    Capacity150L200L250L300L400L500L1000L
    Top Copper Coil (mm*M)Φ16*15Φ16*15Φ16*15Φ16*15Φ16*15Φ16*20Φ19*30
    Bottom Copper Coil (mm*M)Φ16*15Φ16*15Φ16*15Φ16*15Φ16*25Φ16*30Φ19*40
    Polyurethane Foaming (mm)555050506060100
    Outer TankColor Steel Plate/ Enamal White
    Φ470/0.5Φ550/0.5Φ580/0.5Φ580/0.5Φ700/0.5Φ700/0.5Φ1000/0.5
    Inner TankSUS 304 2B , Working pressure-6 bar, Test pressure-12 bar
    Φ360/1.2Φ450/1.5Φ480/1.5Φ480/1.5Φ580*2.0Φ580*2.0Φ800/2.5
    Electrical Heater1500W1500W2000W2000W2000W2000W4000W
    Working StationSR961S (Including controler & WILO PUMP)
    Expansion Tank8L8L8L8L12L12L24L

    Heat Pipe Split Solar Water Heater
    with Double Coils PTS-H2

    Heat Pipe Split Solar Water Heater
    with Double Coils PTS-H2
    ModelPTS-H2-15PTS-H2-20PTS-H2-25PTS-H2-30PTS-H2-40PTS-H2-50PTS-H2-100
    Heat Pipe Solar CollectorTubes (PCS)152025304050100
    Three Target Vacuum TubeDiameter/Length: φ58mm/1800mm; High boron and silicon content 3.3; Structure:Gradual change SS-AL-Nx/Cu selective absorption coating; Vacuum Degree:P<=5*10-3;
    Heat PipeCondesor: φ14*70mm; Thickness: 0.5mm ; Material: red copper TU1+water; Transfer Power:>=150W; Working Pressure:4Mpa; Welding Pressure:4Mpa;
    Outer Shell/Bracket - Alluminum AlloyInsulation Layer - Rock woolDustproof Rubber - EPDMDsily Heat Gain - 8.5MJ/m²
    Inlet/outlet - 22mm/3/4"Tailstock - ABSTemperature - 250 °СWork Pressure - 0.6MPa
    Contour Area2.32m²3.10m²3.78m²4.52m²6.20m²7.56m²15.12m²
    Aperture Area1.43m²1.89m²2.36m²2.83m²3.8m²4.72m²9.44m²
    Absorption Area1.22m²1.62m²2.04m²2.43m²3.24m²4.06m²8.16m²
    Quantity (PCS)15tubes*120tubes*125tubes*130tubes*120tubes*225tubes*225tubes*4
    Water
    Tank
    Capacity150L200L250L300L400L500L1000L
    Top Copper Coil (mm*M)Φ16*15Φ16*15Φ16*15Φ16*15Φ16*15Φ16*20Φ19*30
    Bottom Copper Coil (mm*M)Φ16*15Φ16*15Φ16*15Φ16*15Φ16*25Φ16*30Φ19*40
    Polyurethane Foaming (mm)555050506060100
    Outer TankColor Steel Plate/ Enamal White
    Φ470/0.5Φ550/0.5Φ580/0.5Φ580/0.5Φ700/0.5Φ700/0.5Φ1000/0.5
    Inner TankSUS 304 2B , Working pressure-6 bar, Test pressure-12 bar
    Φ360/1.2Φ450/1.5Φ480/1.5Φ480/1.5Φ580*2.0Φ580*2.0Φ800/2.5
    Electrical Heater1500W1500W2000W2000W2000W2000W4000W
    Working StationSR961S (Including controler & WILO PUMP)
    Expansion Tank8L8L8L8L12L12L24L

    SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar StationSR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar StationSR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station

    SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar StationSR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station

    Product Tags:

    Solar Hot Water Pump Station

      
    Quality SR11L-258 SR21L-258 Solar Hot Water Pump Station Double Pipeline Solar Station for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: JIAXING PASSION NEW ENERGY TECHNOLOGY CO., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)